Institute of Geodynamics · N.O.A. Station health monitoring

HL.ORTH ● OK

Orthonies, Zakynthos · healthy (12V rail)
Position
37.8511, 20.6963 · 450 m
Digitiser
RefTek 130
Last data
Nov. 14, 2026
Inventory
FDSN + archive

Reported by the station

RefTek 130 · RefTek 130 · serial 3607 · fw 3.4.5
from its LOG.L stream · detected Jan. 1, 2026 to Nov. 14, 2026

FDSN inventory · current epoch

reftek130
SensorDescription: “CMG-40T, 30 s, 800 V/m/s-RT130, gain 1, 100 sps”
● Sources agree
Range →

Drag across any chart to zoom every chart to that window — the range control above always scopes all of them together, so the numbers agree.

Supply voltage —V
low 13.00 V on Nov. 2, 2026 — mean min–max in bin
Temperature —°C
— mean min–max in bin
GPS / timing quality —%
— mean min–max in bin
Data completeness —%
— mean min–max in bin
Data completeness, last 30 days
Primary stream coverage Filled bar = data present; notches = gaps. Percentages are of a full 24 h day.
Nov 14 99.93 %
Nov 13 100.00 %
Nov 12 100.00 %
Nov 11 100.00 %
Nov 10 100.00 %
Nov 9 99.99 %
Nov 8 100.00 %
Nov 7 100.00 %
Nov 6 99.99 %
Nov 5 100.00 %
Nov 4 100.00 %
Nov 3 100.00 %
Nov 2 100.00 %
Nov 1 100.00 %
Oct 31 99.99 %
Oct 30 99.99 %
Oct 29 100.00 %
Oct 28 100.00 %
Oct 27 100.00 %
Oct 26 100.00 %
Oct 25 100.00 %
Oct 24 100.00 %
Oct 23 100.00 %
Oct 22 100.00 %
Oct 21 100.00 %
Oct 20 100.00 %
Oct 19 99.99 %
Oct 18 99.99 %
Oct 17 100.00 %
Oct 16 100.00 %
Oct 15 100.00 %
Values
Table view Every plotted value, for readers who need numbers rather than marks.